Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9008903

- Product Categories
- Friendly Links
Information Name: | PD800H-F14 |
Published: | 2012-11-02 |
Validity: | 180 |
Specifications: | Standard |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Wing crown intelligent digital form [PD800H-F14] price. Quality assurance and stable performance [PD800H-F14] Hotline: 13486766633, phone; 0577-62811299 Fax 577 -62819687 Contact: Zhou Business QQ: 7067127 ■ Overview PD800H-F14 is an ideal device for power quality monitoring . The instrument measurement grid electricity, but also can be converted into a 4-way or 2-way test power pulse output function. Distributed detection, the on-site monitoring of the electric power grid, automation control system suitable for transformers, generator sets, capacitor combination motor show. ■ main functions of smart electricity meters, measurements: three-phase current, three rows of LED digital tube display Dimensions 96 * 96mm, hole size 92 * 92mm, optional additional functions: transmission output, relay alarm output, digital communications RS485 PDM utility power monitoring instrument in the digestion technology imports of similar products at home and abroad on the basis of our intelligent monitoring of the running of the electrical equipment and computer design, change product set ammeter monitoring instrumentation, RS485 communication interface link the instrument to the monitoring center computer network, is a high-performance supply and distribution system suitable for China's industrial and mining enterprises, civil construction, building automation and other first-Automation Instrumentation. Pmac dedicated to a comprehensive collection of 50/60hz power supply system power parameters; measurement and display of three-phase current ■ to measuring functional enough high-precision measurement of three-phase power grid system in all common power parameters: three-phase voltage, phase current, active power, reactive power, power factor, grid frequency, reactive power, reactive power, and with a communication interface and power pulse output function. MODBUS-RTU communication protocol, LED-site display and remote RS-485 digital communications. With easy installation, simple wiring, maintenance facilities, a small amount of engineering, field programmable set input parameters, and the ability to complete the different industry PLC, industrial computer networking communication. Measurements: three-phase voltage, current, active power, reactive power, power factor, frequency, active energy, reactive energy metering: the pros and cons to the active energy, inductive capacitive reactive energy: three rows of LED digital display, can be as the high degree of communication: RS485 communication, MODBUS-RTU protocol output: 2-way power pulse output (pulse constant 10000imp/kwh) Extensions: directly from the current, voltage transformer access signal field programmable set input parameters ratio with election : may be additional analog 4-20mA transmitter output, the number of switch, the switch output, monitoring and management of upper and lower-limit alarm function Usage: suitable for a variety of the line loop, large capacity with a complete electrical circuit electrical parameters ■ Key Specifications ■ performance parameters input voltage measured network three-phase three-wire, three-phase four-wire voltage rating AC100V, 400V (when ordering please specify) load duration: 1.2 times the instantaneous: <1VA (2 times / 10s power consumption per phase) impedance> 300kΩ Precision RMS measurement, accuracy class 0.5 the current rating AC1A, 5A (when ordering please specify) load duration: 1.2 times the instantaneous: 2 times the the / 10s power consumption <0.4VA (per phase) impedance <20MΩ precision RMS measurement, accuracy class 0.5 Frequency 40 ~ 60Hz, accuracy 0.1Hz function active, reactive, apparent power, four-phase limit measurement accuracy of 0.5 power, active precision 0.5 reactive accuracy a programmable switch, circulation LED display power operating range AC, DC 80 ~ 270V power consumption ≤ 5VA output digital interface RS-485, MODBUS-RTU protocol pulse output 2-way power pulse output, optocoupler isolation environment working environment -10 ~ 55 ℃ Storage environment -20 ~ 75 ℃ safety withstand voltage input and power supply> 2kV, input and output> 2kV, power supply and output> 1kV insulation input, output, power chassis> 5MΩ dimensions 120 × 120 × 128 96 × 96 × 128 (length, width, D) Weight 0.6kg ■ installation method 1). fixed distribution cabinet, choose the right place to open a hole size of the mounting holes. 2) Remove the instrument, loosen the set screw, remove the retaining clip. 3) install the meter meter hole into the distribution cabinet. 4) insert meter retaining clip, fixed positioning screws. Note: LN auxiliary power press the wiring diagram of the instrument housing correct wiring! ■ Auxiliary power Multifunction Power Meter pz568e have universal switching power supply (AC / DC) input interface, if not to make a special statement provided 220V (AC / DC) or 110V (AC / DC) power supply interface standard instrument limit operating supply voltage of the AC / DC :80-270V, please ensure that the power is applied to the products above to prevent damage to the product. A AC power suggested 1A fuse is installed in the line of fire on one side. B is recommended for areas of poor power quality, prevent lightning strikes, as well as a rapid burst suppressor surge suppressors installed in the power supply circuit. ■ measuring Multifunction Power Meter can measure the power grid parameters: Ua, Ub, Uc (phase voltage); Uab, Ubc Uea (line voltage) Ia, Ib, Ic (current); Pa, Pb, Pc ps (per phase active power and total active power); Qa, Qb, Qc, Qs (each phase reactive power and total reactive power); the PFs (total power factor); Ss (total apparent power); FR (frequency ) as well as active (reactive) energy, electricity measurement parameters save all the instrument internal power table, instrument digital communication interface accessible collection of these data. And for different models of the instrument, which displays the contents and methods but may be inconsistent, refer specifically described. The following national sales Yongguan appliances: Anhui Province: anqing City; Bengbu City; Bozhou City; the Chaohu City; Chizhou; Chuzhou; Fuyang City; Hefei; declared city of Huaibei City; Huainan City; Huangshan City; Lu'an City ; Maanshan City; Suzhou City; Tongling City; Wuhu City; Gansu Province: Silver City; Dingxi City; Gannan Tibetan Autonomous Prefecture; Jiayuguan City; Jinchang City; Jiuquan City; Linxia Hui Autonomous Prefecture in Lanzhou City; Longnan; Pingliang City; Qingyang City ; Tianshui City Laibin; the Wuwei City; Guangdong Province, Zhangye City: Dongguan City; Foshan; Guangzhou; Jiangmen City; Meizhou; Qingyuan City; Shenzhen; Zhaoqing City, Guangxi Province: Chongzuo City; Fangchenggang City; Hezhou;, ; Liuzhou; Nanning; Qinzhou City; Wuzhou; Yulin City, Guizhou Province: Anshun City; the Bijie areas; Guiyang; Liupanshui City;; Tongren Prefecture; Zunyi City |
Admin>>>
You are the 16217 visitor
Copyright © GuangDong ICP No. 10089450, Yueqing City Love Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 16217 visitor
Copyright © GuangDong ICP No. 10089450, Yueqing City Love Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility